Member Information and Posts by Harvard
from the Control department...
Modbus protocol, HVAC system control
Topic: Communications systems and equipment.
Originally posted by JD on 13 August, 2009 - 1:14 pm
Return strings from Modbus simulator application differ from that of HVAC system harware
New Replies:
It is not unusual to have byte reversal issues. One of the devices, Host or Slave, should have a...
from the Forum department...
Convert SIMATIC to MODBUS address
Topic: PLCs and related questions.
Originally posted by martin on 12 August, 2009 - 1:02 pm
Convert SIMATIC to MODBUS address
New Replies:
To poll Address 11, Reg 40001 for 2 Regs: 0B 03 00 00 00 02 C4 A1 To poll Address 12 register...
from the Forum department...
Modbus frame size
Topic: Communications systems and equipment.
Originally posted by Bin on 6 August, 2009 - 5:25 am
Can I use the Modbus frame size larger than 256 bytes?
New Replies:
No! If you notice in the Function Code 3 slave response the 3rd byte is the byte count of the data...
from the Forum department...
MODBUS and flow meter
Topic: Software, including programming, OS issues, etc.
Originally posted by zabee on 29 July, 2009 - 1:26 am
how a flow meter communicate
New Replies:
I think you are saying you need to convert pulses from the flow meter to an accumulator that...
from the RS-485 department...
Modbus ASCII RS-485
Topic: Communications systems and equipment.
Originally posted by Vinod Gavande on 29 July, 2009 - 1:32 am
How many slave devices cab be multidroped on RS-485 bus?
New Replies:
The Master is just another device, so 32 including the Master is your correct answer. Remember, the...
from the Design department...
Modbus RTU protocol format with ODD PARITY
Topic: Communications systems and equipment.
Originally posted by vijeta on 1 July, 2009 - 1:45 am
What is the MODBUS RTU PROTOCOL format for ODD PARITY?
New Replies:
Parity is redundant and never normally used WHEN CRC error checking is implemented. Parity is not...
from the Forum department...
Software simulator as Modbus device
Topic: Communications systems and equipment.
Originally posted by dan on 16 June, 2009 - 6:29 pm
Modbus adaptor
New Replies:
I think you are asking for a ModBus Slave Simulation application that will respond to any ModBus...
from the Automation & Control department...
MODBUS Analog Input
Topic: Local and wide area networking in factory automation.
Originally posted by Tashar on 9 June, 2009 - 12:41 am
Does a MODBUS AI (MAI) make sense??
New Replies:
Modbus has Holding Registers and Input Registers. You cannot write to a Input Register, it is for...
from the Networking department...
Modbus RTU Passive Taps
Topic: Local and wide area networking in factory automation.
Originally posted by Shawn H on 29 May, 2009 - 11:55 am
How long can the taps on a modbus network be and are you limited to the amount of taps for 32 devices?
New Replies:
RS485 2 wire 1/2 duplex cannot have any "Tap length". There are only 2 ends to an RS485...
from the Forum department...
micrologix 1400 and modbus rtu woes.
Topic: Communications systems and equipment.
Originally posted by blackj on 19 May, 2009 - 4:26 pm
a question about modbus function codes, as well as looking for help with micrologix1400
New Replies:
Modicon Register 40001 is Modbus Register 0. The correct poll is: 01 03 00 00 00 02 C4 0B ...
from the Can't talk to SATEC meter department...
MODBUS Communications Tester
Topic: Communications systems and equipment.
Originally posted by Thomas Toms on 27 April, 2009 - 2:52 pm
PLC Modbus Master will not talk to SATEC power measurement meter.
New Replies:
I have a freeware Win32 Console application that will monitor two RS232 1/2 duplex data streams...
from the Different versions of Modbus? department...
Modbus RTU on ABB AC250
Topic: PLCs and related questions.
Originally posted by Laban on 2 April, 2009 - 8:11 am
Are there different dialects of Modbus?
New Replies:
While there are variations I have never seen something as you describe. Here are two write...
from the Forum department...
Do you recognize this error checking?
Topic: Software, including programming, OS issues, etc.
Posted by Harvard on 31 March, 2009 - 11:23 am
Do you recognize this error checking?
from the Forum department...
connect multiple devices to RS-232
Topic: PLCs and related questions.
Originally posted by Abhijeet on 26 March, 2009 - 6:55 am
connecting multiple devices to modbus over rs-232 by using RS-232 to RS-485 converter
New Replies:
According to the Gould Modbus Protocol Reference Guide PI:MBUS-300 Rev B, a Function Code 7 has a 4...
Topic: Communications systems and equipment.
Originally posted by Mikey on 19 March, 2009 - 8:51 pm
modbus analyzing from the outside
New Replies:
Most likely caused by timing settings. I would verify the Slave "Turnaround Time" setting...
Topic: Local and wide area networking in factory automation.
Originally posted by ASh on 16 February, 2009 - 6:36 am
Problem connecting 2-wire modbus RS-485 to 3-wire Modbus RS-485 on daisychain modbus network.
New Replies:
Start with the MOXA 3180 and add one slave at a time. Do not be suprised if the Data+ and Data-...
Topic: Engineering and workplace issues.
Originally posted by Timothy Burgess on 5 February, 2009 - 3:26 pm
Problems talking to a slave machine using the Modbus RTU protocol.
New Replies:
You will not get a response from a Modbus slave if the CRC is in error, it will be assumed to be...
Topic: Communications systems and equipment.
Originally posted by interop on 3 February, 2009 - 12:04 pm
Can only read 6 registers from Controlotron 1010 flow meter via Modbus
New Replies:
If this connection is Modbus RTU protocol then you would not want to be using parity and 7 bits....
from the Help with modbus RTU department...
Elpro 905u G / Adams 5000
Topic: Communications systems and equipment.
Originally posted by Adam Rayner on 1 February, 2009 - 12:03 am
Trying to read Reg 400001 from a Adams 5000E to a elpro 905u-G
New Replies:
>So should i set the radio to read register 40001 or just 0?< Probably 40001 and it will...
Modicon Register 400001 is a misprint, should be Modicon Register 40001 which is polled as ModBus...
1
 
 
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2009 Nerds in Control, LLC. All rights reserved.