1
Control.com member...
Member Information and Posts by scadametrics
from the Forum department...
Low cost modbus meters
Topic: Application Questions and Problems
Originally posted by Raj on 16 November, 2009 - 4:32 pm
Low cost power meter-data acquisition.
New Replies:
Raj, I was not able to tell whether you need 3-phase or single-phase and whether this is for...
from the Forum department...
Modbus TCPIP master to many slaves
Topic: Communications systems and equipment.
Originally posted by Miroslav on 30 October, 2009 - 6:03 am
Modbus TCPIP master to many slaves
New Replies:
Miroslav, If your slaves (servers) support Modbus/UDP, then you could use Modbus/UDP as an...
from the Thanh department...
Communication between DCS and Modbus
Topic: Continuous process industries, DCS questions.
Originally posted by Pham Trung Thanh on 22 October, 2009 - 11:43 pm
Question about connection between two control units
New Replies:
Roy, that was my question, too. Regarding the protocol used by the DCS, 'Ethernet' just isn't...
from the Automation department...
Modbus Slave Simulator
Topic: Communications systems and equipment.
Originally posted by Nishith Shetty on 21 October, 2009 - 4:00 am
Connect an Modbus Slave Simulator to Scada
New Replies:
Nishith, Simply Modbus offers a Modbus Slave Simulator. Here is a link to their website: ...
from the Modbus Protocol department...
Modbus/NTP Interface
Topic: Communications systems and equipment.
Originally posted by gc05 on 16 October, 2009 - 4:38 am
NTP/Modbus interface for time-stamping
New Replies:
There is no practical limit to the number or protocols that can be sent via a single Ethernet port....
gc05, NTP, as far as I know, is a network protocol for time-synchronization --- in other words,...
Topic: Communications systems and equipment.
Originally posted by Steve on 18 October, 2009 - 12:30 pm
Water/Gas Meter with Modbus/LonTalk/BACnet Compatibility
New Replies:
Hello Steve, For your application, I recommend using a Sensus (or Sensus-compatible) water meter...
from the Forum department...
MODBUS and flow meter
Topic: Software, including programming, OS issues, etc.
Originally posted by zabee on 29 July, 2009 - 1:26 am
how a flow meter communicate
New Replies:
For your application, I recommend using a Sensus water meter and a Sensus gas meter, both of which...
I believe that you will need two pieces of software... one for data collection/communication via...
zabee, If you wish to interrogate totalization and flow rate from water meters, then my company...
Vahid, The 7955, depending upon which communication options it has, may support MODBUS/RTU or...
What is the brand and model of the flow meter? And what is the flow meter monitoring (water, gas,...
from the Forum department...
Modbus Data Logger
Topic: PLCs and related questions.
Originally posted by Vineeth on 4 September, 2009 - 5:45 pm
Log data from serial ports.
New Replies:
I made a mistake on the link. Try this one... http://scadametrics.com/blog/?p=22 ...
Glad that my solution was helpful, Vaneeth. My snooper program was written in C and compiled in...
Vaneeth, I did something like this once, but with a twist that may make your job easier. In...
Topic: Application Questions and Problems
Originally posted by Argolo on 30 April, 2005 - 12:08 am
I need equipment for converting a pulse/frequency signal from a flow meter (compound for waste water flow) to MODBUS RTU SLAVE Protocol.
New Replies:
Argolo, What is the brand and model of the flow meter? ...
from the Assistance Required department...
Modbus TCP/IP device via RS232
Topic: PLCs and related questions.
Originally posted by Glyn on 7 August, 2009 - 5:12 pm
Need a 'software serial port' that will allow my modbus RTU software to communicate with a modbus TCP/IP device
New Replies:
I don't know about a software solution, but I have experience using the Digi One IAP, which...
from the Forum department...
Modbus to HART converter ?
Topic: Communications systems and equipment.
Originally posted by moduser on 31 July, 2009 - 4:41 am
Is it possible to convert Modbus signal from a field device to HART either in the field or in safe area ?
New Replies:
Here's an old thread with some info regarding modbus->hart conversion... ...
from the Forum department...
Wireless Pressure Transducer
Topic: Sensor technologies.
Originally posted by Brett on 9 June, 2009 - 10:58 am
Wireless Pressure Transducer
New Replies:
Keller America offers a Modbus/RTU Slave (RS-485) pressure transducer that can be mated with a...
Topic: Communications systems and equipment.
Originally posted by James on 28 May, 2009 - 11:53 am
Modbus Connection AB CompactLogix - Mitsubishi A2ACPUcomm
New Replies:
To answer this question fully, I'm pretty sure we need to know which of these PLC's is to be the...
1
 
 
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2009 Nerds in Control, LLC. All rights reserved.